存在的记忆

登陆F663N或HG8245猫的超级密码是什么


大过年,家里网络频繁掉线,查了一些路由器的超级用户,登录后看一下日志
登陆移动中兴F663N或华为HG8245猫的超级密码!

华为HG8245猫的超级密码→用户名:telecomadmin,密码:nE7jA%5m
移动中兴F663N猫的超级密码→用户名:CMCCAdmin  密  码:aDm8H%MdA

报错日志

2021-02-12 17:20:49 [Error] [reg_mgr] call KILL_TIMER(1) check Tmid[0] Error!
2021-02-12 17:27:08 [Error] [][00010000] Send task Message[0XA506] to [00810301] in SocketAsynSendMsg()  ERROR !
2021-02-12 17:27:32 [Error] [][00010000] Send task Message[0XA506] to [00810301] in SocketAsynSendMsg()  ERROR !
2021-02-12 17:29:02 [Error] [reg_mgr] call KILL_TIMER(1) check Tmid[0] Error!
2021-02-12 17:31:15 [Error] [reg_mgr] call KILL_TIMER(1) check Tmid[0] Error!
2021-02-12 17:31:15 [Error] [reg_mgr] call KILL_TIMER(2) check Tmid[0] Error!
2021-02-12 17:31:15 [Error] [reg_mgr] call KILL_TIMER(1) check Tmid[0] Error!
2021-02-12 17:31:15 [Error] [reg_mgr] call KILL_TIMER(2) check Tmid[0] Error!
2021-02-12 17:31:17 [Error] [reg_mgr] call KILL_TIMER(1) check Tmid[0] Error!

查错处理记录
1.看日志报错,发送光功率过低.可以判断是光猫或者上游设备有问题

2.根据经验判断运营商olt上检测并下发的,发射功率1.5dbm还算正常,常规家用设备故障无非就是接头或者设备,设备过年现在没人换,重新插拔下光纤连接的那个接头看一下效果

3.发送光功率有点低,正常是(2.2)我这边没办法测试功率,不过根据报错也可以判断。怀疑是光纤被折过,重新仔细检查一下光纤是否有弯折过大的地方,发现果然个有折的,重新折回来,再观察观察。

4.今天第三天,问题没有复现,确定是光纤被弯折。

参考文档
光猫日志报错
路由器超级密码